| Specific Gravity Range | 0.8000 - 0.9000 (0.7500 - 0.8500) Chang-over switch |
| Specific Gravity Accuracy | ±0.003 |
| Temperature Correction for Specific Gravity | Built-in temperature correction circuit (20C conversion) |
| Moisture compensation of Flux | Moisture compensation circuit built-in.(0% conversion) |
| Liquid Depth Management | Between 5mm of the upper/lower limits. |
| Temperature measurement Range | 0C~50C (Pt Temp. Sensor) |
| Temp. Accuracy | ±0.5C |
| Moisture rate measuring range in liquid | 0 ~ 9.9% |
| Moisture rate accuracy | ±1% |
| Supply method of liquid (Pump Capacity) | Automatic pump supply (Head:1m, 500ml/min) |
| Liquid Empty Alarm | Automatically signals alarm: buzzer & LED (red), output relay |
| Usage Tank | 18L (direct use possible) |
| Output Relay | Digital : RS232C, B9600, C8, NP, S1 Analog : DC4-20mA |
| Sensor Cord | 3m |
| I/O tube | 6m |
| Material Quality | Vinyl Chloride, Stainless Steel, Viton, PE, PP, Fluorocarbon, PA, Polyurethane, and EPT |
| Operation Temperature | 10℃~50℃ |
| Power Supply | AC100V (or AC200V) 50Hz/60Hz |
| Power Consumption | Rating: 35VA |
| Fuse | 2A |
| Weight | 11kg |