MALCOM RCX-GL seriesREFLOW CHECKER MODULAR TYPE
  • Summary
  • Parameter
  • Application
  • 资料
  • Related
  • Brand
  • Video

     RCX-GLseries Feature:

    You can freely add and configure the necessary functions (temperature measurement 6ch) core unit.

    We have prepared a unit wind speed, oxygen concentration and temperature measurement camera 12ch required 
        to manage the reflow process.

      Special program by the system, displayed on the screen the same oxygen concentration, wind speed camera 
        images.

      The support functions in the profile condition is easy to create a profile.

    For easy to obtaining and exchange, power supply is AAA battery.

      in the wireless data transfer is possible to adopt a new BLUETOOTH.


     REFLOW CHECKER MEMORY UNIT (6 CHANNELS RCM-S):

    Feature

    ・Temperature measured in units of the underlying system.

    ・New features such as Bluetooth, OK/NG judgment function, Thermocouple response and AAA batteries.


    Specification

    Item

    Specification

    Model Name

    RCX-S

    Main Unit

    RCM-S

    Measuring Temp. Range

    0~500℃ *1

    Max Measuring Time

    Approx. 10 hours * 1 * 2

    Sampling Time (sec.) /Max. Storage Time

    0.05sec./4h50min, 0.1sec./10h40min, 0.2sec./21h20min, 0.5sec./48h20min,1.0sec/96h40min, 2.0sec./193h20min, 4.0sec/386h40min,8.0sec./773h20min Arbitrary  setup possible

    Temperature Accuracy

    ±1℃

    Measuning Points

    1-6 Points

    Heat Resistant Connector

    Miniature Connector

    Input

    Thermocouple JIS-K 1kΩ max.

    0.1 10m

    Power Supply

    AAA battery

    Manganese batteries Alkaline battery Nickel-metal   hydride

    Outer dimensions

    Memory unit (w/o Heat resistant   case) 55 (W) x 170 (D)   x 18 (H) mm 200g

    Heat resistant case: 65 (W)   x 245 (D) x 25 (H) mm 370g

    Data Transmission Method

    USB, Bluetooth

    Weight

    Approx. 570g (Heat resistant case and   battery are included)

    * 1 It differes from the heat resistant time of memory unit.

    * 2 It is the experimental value by AAA battery. The max. measuring time depens on battery capacity.

    * The above specifications are subject to change without notice.


     REFLOW CHECKER MEMORY UNIT (PLUS α 6 CHANNELS RCM-T):

    Feature

    ・12ch measurement is possible by adding to RCM-S memory unit.

     

    Specification

    Item

    Specification

    Model   Name

    RCX-T

    Main Unit

    RCM-T

    Measuring   Temp. Range

    0℃~500℃※1

    Max   Measuring Time

    Approx. 3hours※1

    Sampling   Time (sec.)

    0.05, 0.1, 0.2, 0.5, 1.0, 2.0, 4.0, 8.0

    Temperature   Accuracy

    ±1℃

    Measuning   Points

    1~12poionts

    Heat   Resistant Connector

    Miniature   Connector

    Input

    Thermocouple   JIS-K 1KΩ max. (φ0.1 10m)

    Outer   dimensions

    Memory   unit (w/o Heat resistant case) 55 (W) x 253 (D) x 18 (H) mm ※ 2

    Heat   resistant case: 65 (W) x 328 (D) x 25 (H) mm ※2

    * 1 It differes from the heat resistant time of memory unit.

    * 2 It is the experimental value by AAA battery. The max. measuring time depens on battery capacity.

    * The above specifications are subject to change without notice.


     REFLOW CHECKER MEMORY UNIT (RCX-C):

    Feature

    ・Monitor a video of observation in the reflow oven.

    ・A removable carmera enables to obserrve from various angles.

    Specification

    Item

    Specification

    Model   Name

    RCX-C

    Main   Unit

    RCM-C

    Camera

    Separate   type, Heat-resistant color camera

    Cable   length

    50cm   (scheduled)

    Moving   image format

    ASF (scheduled)

    Max   Recording time

    10min   (Battery and heat resistant time are not included)

    Outer   dimensions

    Camera   unit : 44 (W) x 84 (D) x 19 (H) mm ※ 1

    Heat   resistant case: 65 (W) x 370 (D) x 25 (H) mm ※2

    * 1 It differes from the heat resistant time of memory unit.

    * 2 It is the experimental value by AAA battery. The max. measuring time depens on battery capacity.

    * The above specifications are subject to change without notice.


     REFLOW CHECKER MEMORY UNIT (PLUS α O2 CONCENTRATION MONITOR RCM-O) :

    Feature

    ・Measure the oxygen concentration profile in the furnace.

     

    Specification

    Item

    Specification

    Model   Name

    RCX-O

    Main   Unit

    RCM-O

    Max. measuring   time

    Ni-MH   battery: Approx. 40min.

    Sampling   time

    0.05sec. 0.1sec. 0.2sec. 0.5sec. 1.0sec. 2.0sec. 4.0sec. 8.0sec.

    Arbitrary   setup possible (synchronized to RCM-S memory unit)

    Oxygen

    Measurement   principle

    Zirconia   limiting current method

    Measurement   range

    50ppm~5000ppm

    Measurement   accuracy

    50ppm~1000ppm±5%FS

    1000ppm~5000ppm±10%FS

    Power   supply

    Supplied   from RCM-S Memory unit

    Ni-MH   battery (AAA battery x 3)

    Outer   dimensions

    65(W)×383(D)×25(H)(㎜) Excluding projections

    Weight

    Approx. 950g (including   battery, tray is not included)

    * The maximum measuring time is a time in which heat resistance is not considered, and it cannot be measured 
         in the reflow oven.

    * Manganese batteries and alkaline batteries are not available.

    * Lithium-ion secondary battery or AAA battery is selectable at the time of order.

    * The above specifications are subject to change without notice.


     REFLOW CHECKER MEMORY UNIT (PLUS α AIR VELOCITY MONITOR RCM-W) :

    Feature

     ・Measure the wind speed profile.

     

    Specification

    Item

    Specification

    Model   Name

    RCX-W

    Main   Unit

    RCM-W

    Measurement   accuracy

    ±5% +   0.1m/s of the indicated value

    Sampling   time (sec.)

    0.5

    The   number of measuring points

    1point

    Outer   dimensions

    Memory   unit (w/o Heat resistant case): 55 (W) x 210 (D) x 18 (H) mm 
      ※ 1

    Heat   resistant Case: 65 (W) x 245 (D) x 25 (H) mm ※2

    * 1 It differes from the heat resistant time of memory unit.

    * 2 It is the experimental value by AAA battery. The max. measuring time depens on battery capacity.

    * The above specifications are subject to change without notice.


Follow us:

Copyright © 1999-2017 Hapoin Enterprise 沪 ICP 备 11051220 号 沪公网安备 31010502002237号All Rights Reservedbottom.png