CORES core9050bHigh temperature observation
  • Summary
  • Parameter
  • Application
  • Data
  • Related
  • Brand
  • Video

    Since the enforcement of the RoHS Directive on July 1, 2006, there has been a growing trend in the shift to using lead-free solders for the surface mounting process to produce various electric and electronic devices.

    Lead-free solders, requiring much higher temperatures when applied in the reflow furnaces, however, have created various serious problems such as poor soldering wettability, coplanarity, warpage or twisting of connectors, SMDs and other devices on the production lines.

    CORES, to cope with these problems, taking advantages of its know-how and expertise relating to its own similar shape observation modules using thermal control, has developed core9050b, which provides similar environmental conditions to real reflow furnaces and permits easier inside observations from wide angles.

     

    core9050b, thus, enables you to look to see the wettability of applied solders when they are melting at high temperatures as well as every shape change or deformity of target work pieces.

     

    Real-time observations on solder wettability at high temperatures

    core9050b adopts a most SDM-friendly convectional heating method and has allowed the realization of excellent thermal conductivity efficiency and the duplication of similar environmental conditions of reflow furnaces applying lead-free solders.

     

    Omni-directional observations from wide angels of 360°horizontally and 180°vertically

    core9050b, equipped withCORES’ epoch-making dome-shaped hemispherical glass, permits omni-directional visual observations of any shape change of electric and electronic devices and PWBs. Its spotlighting, capable of easy light amount and zoom lens adjustment, provides core9050b with fully sufficient depth of field and clear images for super minute observations of the target.


    General

    Name

    Reflow scope

    Type

    core9045a

    Power

    100VAC ± 5%(50 / 60Hz)

    Power consumption

    Main unit:1400VA  Control unit : 300VA

    Supply air pressure

    0.6MPa ~ 0.9MPa

    Air consumption

    200L/min

    External dimension

    Main unit W 450mm × D 405mm × H 306mm

    Control unit W 235mm× D 400mm× H 375mm

    Weight

    Main unit 19Kg  Control unit 19Kg

    Ambient operating temperature

    25℃±5℃

    Heating

    Heater

    100V 350W×4

    Heater life

    Approx. 5000h

    Heating method

    Convection by hot air

    Heating temperature

    Room temperature to 300°C

    Heating area

    W 50mm × D 50mm × H 20mm

    Temperature control

    Controlled by temperature controller and thyristor unit,

    monitoring the temperature with thermocouples.

    Camera

    Photograph elements

    1/3” interline

    Total pixel number

    380,000 pixels in colour

    Converted amplification

    Standard magnification:(×8 ~ 64) ( Standard )

    High magnification:(×32 ~ 256) ( Option )

    ( Resolution1,280 x 1,024 pixels on 19’ monitor )

    Photograph area

    Standard magnification:W 25.0mm × D 18.8mm ~ 2.9mm × H 2.2mm

    High magnification:W 6.3mm × D 4.8mm ~ 0.8mm × H 0.6mm


    W.D

    Standard magnification: 82 mm High magnification: 83 mm

    Lighting

    Light source       

    100 W halogen lump

    Light lifetime

    1000 h

    Average lux

    600000 lux

    Power

    130 VA

    Others

    Temperature profile

    Up to 16 temperatures can be designated in the profile.

    Data storing

    Temp.,time and animations(AVI,COR*MPG)can be recorded as per 30 frame/sec and

    still pictures(BMP,JPG) as snapshots.

    Logger unit

    Temperatures of max 8 points(via 8 channels) of the target piece can be measured

    with thermocouples and in accordance with the temperature profile.

    The measured data can be saved in CSV.


Follow us: