TENNEY T5ST/10ST/15ST/27ST/36ST/48ST/64STStrat Altitude Chambers
  • 概述
  • 参数
  • 性能
  • 资料
  • 相关产品
  • 品牌
  • 视频

    Strat Altitude Chambers T5ST/10ST/15ST/27ST/36ST/48ST/64ST


    Tenney’s Tenney Strat Altitude Chambers simulate altitudes up to 200,000 feet. With an overall temperature range of -70°C to +177°C, humidity capabilities of 20% to 98% RH, and workspace sizes ranging from 5- to 64-cubic-feet, this highly developed line of altitude chambers offers one of the broadest selections in the industry. 

    We are confident that our solid altitude chamber construction and precise operating systems will provide the exacting performance and a high degree of reliability for your altitude testing needs.


    Strat Altitude Chambers T5ST/10ST/15ST/27ST/36ST/48ST/64ST Features:


    Continuously welded, stainless steel, vapor-tight interior liners 

    Control tolerance is ±0.3°C and ±2% RH typical after stabilization

    Linear pressure transducer to measure altitude 

    Non-corroding humidity system

    Low-water protection on humidity system

    Vertical-down recirculating conditioning stream




    Strat Altitude Chambers  Specifications:


    Model

    T5ST

    10ST

    15ST

    27ST

    36ST

    48ST

    64ST

    System Horsepower

    Size

    4

    6

    15

    6

    15

    6

    15

    20

    6

    15

    20

    15

    20

    30

    15

    20

    30

    Workspace inches (mm)

    W

    21/53

    (533/1346)

    24/61

    (610/1549)

    24/61

    (609/1549)

    36/91

    (914/2311)

    36/91

    (914/2311)

    48/122

    (1219/3099)

    48/122

    (1219/3099)

    D

    21/53

    (533/1346)

    24/61

    (610/1549)

    36/91

    (914/2311)

    36/91

    (914/2311)

    48/122

    (1219/3099)

    36/91

    (914/2311)

    48/122

    (1219/3099)

    H

    25/51

    (635/1295)

    30/76

    (762/1930)

    30/76

    (762/1930)

    36/91

    (914/2311)

    36/91

    (914/2311)

    48/122

    (1219/3099)

    48/122

    (1219/3099)

    Exterior inches (mm)

    W

    25/51

    (635/1295)

    51/130

    (1295/3302)

    52/130

    (1320/3302)

    63/160

    (1600/4064)

    63/160

    (1600/4064)

    77/196

    (1956/4978)

    77/196

    (1956/4978)

    D

    63/152

    (1600/3860)

    99/203

    (2515/5156)

    111/236

    (2819/5994)

    111/241

    (2819/6121)

    123/272

    (3124/6909)

    123½ / 281

    (3131/7137)

    135½  / 312

    (3435/7924)

    H

    78/183

    (1981/4648)

    84/210

    (2134/5334)

    84/213

    (2134/5410)

    90/229

    (2286/5817)

    90/229

    (2286/5817)

    91/231

    (2311/5867)

    91/231

    (2311/5867)

    Utilities, etc .

    Heater Capacity

    2

    4

    6

    8

    8

    16

    16

    Humidifier

    Watts

    1

    2

    3

    GPH

    1 .05

    1 .0

    1 .5

    AMPS @ 230V, 33

    33(1)

    48

    81

    52

    85

    63

    96

    130

    63

    96

    130

    120

    149

    183

    120

    149

    183

    AMPS, Fuse

    45

    70

    110

    70

    120

    80

    125

    175

    80

    125

    175

    150

    200

    250

    150

    200

    250

    Cooling Water, 20°C GPM

    -

    3

    6

    3

    6

    3

    6

    9

    3

    6

    9

    6

    9

    12

    6

    9

    12

    Unit Weight

    Lbs/Kg

    1300/590

    3150/1429

    4850/2200

    3150/1429

    6550/2971

    11,500/5216

    13,050/5920


    Tenney Strat Altitude Chambers Options


    Humidity capability: 20% to 98% RH in the temperature range of +20°C to +85°C as limited 

    by a 3-degree dew point.

    Humidity not achieved simultaneously with altitude.

    Add suffix "R" to model number for humidity.

    Vacuum performance: All chambers achieve altitude up to 100,000 feet (8.2 mm Hg) in 35 minutes. 

    Optional features extend altitude capabilities to 200,000 feet (0.17 mm Hg). 

    Combined temperature and altitude to 60,000 feet maximum.

    Test data based on a 24°C ambient, sea level, 60 Hz. Performance slightly reduced on 50 Hz. 

    Power requirements based on standard vacuum pump.